| Product characteristics |         
                    | Output function |             normally closed |         
                    | Sensing range [mm] |             3...15 |         
                    | Housing |             Threaded type |         
                    | Dimensions [mm] |             M30 x 1.5 |         
                    | Electrical data |         
                    | Operating voltage [V] |             20...250 AC/DC |         
                    | Protection class |             II |         
                    | Reverse polarity protection |             no |         
                    | Outputs |         
                    | Output function |             normally closed |         
                    | Max. voltage drop switching output DC [V] |             8 |         
                    | Max. voltage drop switching output AC [V] |             10 |         
                    | Minimum load current [mA] |             5 |         
                    | Max. leakage current [mA] |             2.5 (250 V AC) / 1.7 (110 V AC) / 1.5 (24 V DC) |         
                    | Permanent current rating of switching output AC [mA] |             200; (250 (...50 °C)) |         
                    | Permanent current rating of switching output DC [mA] |             200; (250 (...50 °C)) |         
                    | Short-time current rating of switching output [mA] |             1500; (20 ms / 0,5 Hz) |         
                    | Switching frequency AC [Hz] |             25 |         
                    | Switching frequency DC [Hz] |             50 |         
                    | Short-circuit proof |             no |         
                    | Overload protection |             no |         
                    | Monitoring range |         
                    | Sensing range [mm] |             3...15 |         
                    | Sensing range adjustable |             yes |         
                    | Factory setting sensing range [mm] |             15 |         
                    | Real sensing range Sr [mm] |             15 ± 10 % |         
                    | Operating distance [mm] |             0...12.1 |         
                    | Accuracy / deviations |         
                    | Correction factor |             glass: 0.4 / water: 1 / ceramics: 0.2 / PVC: 0.2 |         
                    | Hysteresis [% of Sr] |             1...15 |         
                    | Switch-point drift [% of Sr] |             -15...15 |         
                    | Operating conditions |         
                    | Ambient temperature [°C] |             -25...70 |         
                    | Protection |             IP 65 |         
                    | Increased immunity |             yes; (Increased immunity to conducted radio frequency interference) |         
                    | Tests / approvals |         
                    | EMC |                                      |         
                    | MTTF [years] |             302 |         
                    | Mechanical data |         
                    | Weight [g] |             126.5 |         
                    | Housing |             Threaded type |         
                    | Mounting |             non-flush mountable |         
                    | Dimensions [mm] |             M30 x 1.5 |         
                    | Thread designation |             M30 x 1.5 |         
                    | Material |             PBT |         
                    | Displays / operating elements |         
                    | Display |                                                                                                     | Switching status |                         1 x LED, yellow |                                                                |         
                    | Electrical connection |         
                    | Required protection |             miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting |         
                    | Accessories |         
                    | Items supplied |                                                                                                     | lock nuts: 2 |                                                                  | screwdriver: 1 |                                                                |         
                    | Remarks |         
                    | Remarks |                                                                                                     | Recommendation: check the unit for reliable function after a short circuit. |                                                                |         
                    | Pack quantity |             1 pcs. |         
                    | Electrical connection - plug |         
                     |             Cable: 0.1 m, PVC; 2 x 0.5 mm² |         
                     |             Connector: 1 x 1/2" |